Illustrative scenario

Night setback that never happened

Illustrative scenario — representative of common industrial IoT applications

Energy & electricityBulk Handling & Rail Logistics

The overnight setback had silently stopped working — and it was worth about a third of the load.

A distribution warehouse

No client is named, no logo is shown and no figure here was measured at any site (R2).

How it went.

Every study on this site runs the same four beats, in the same order.

  1. 01

    Alert

    The building automation schedule said the setback was active. The electrical trace said otherwise, every night, for months.

  2. 02

    Cost

    ~35% of overnight electrical load — Recovered by restoring a setback schedule that had failed silently.

  3. 03

    Fix

    Current transformers on the main HVAC feeds · Minute-resolution demand trending · Overnight baseline alerting

  4. 04

    Restored

    A schedule that is measured, and alerts when it is not

In full.

Illustrative scenario — representative of common industrial IoT applications.

The problem

The building automation schedule said the setback was active. The electrical trace said otherwise, every night, for months.

What would be installed

  • Current transformers on the main HVAC feeds
  • Minute-resolution demand trending
  • Overnight baseline alerting

What changes

Before — A schedule that was believed to be working After — A schedule that is measured, and alerts when it is not

The number

~35% of overnight electrical load — Recovered by restoring a setback schedule that had failed silently. Illustrative scenario, not a client result. Figure is representative, not measured. [TOM-REVIEW]

In one line

A control system reports what it was told to do. A meter reports what happened.

What the data looked like.

Hover or arrow-key across the trace to read any interval. The flagged point is the one that started the conversation.

Night setback that never happened
SETBACK TARGETOccupied schedule onSetback never landedabout 35% of the overnight load
HVAC DEMAND · LAST 24 H · 30-MIN BUCKETS · DASHED = BASELINE
Chart data
IntervalHVAC feed (kW)
00:00114
00:30113
01:00111
01:30117
02:00113
02:30115
03:00116
03:30115
04:00114
04:30115
05:00115
05:30115
06:00131
06:30133
07:00131
07:30131
08:00135
08:30131
09:00135
09:30134
10:00129
10:30133
11:00133
11:30132
12:00131
12:30129
13:00133
13:30131
14:00134
14:30135
15:00135
15:30129
16:00129
16:30134
17:00131
17:30134
18:00116
18:30112
19:00116
19:30117
20:00113
20:30113
21:00111
21:30116
22:00115
22:30117
23:00112
23:30117
Before and after, in words
BeforeA schedule that was believed to be working
AfterA schedule that is measured, and alerts when it is not

Illustrative dataset — a representative operational profile, seeded and deterministic, not measured at any site.

What changed.

Before

A schedule that was believed to be working

After

A schedule that is measured, and alerts when it is not

~35%

of overnight electrical load

Recovered by restoring a setback schedule that had failed silently.

Source: Illustrative scenario, not a client result. Figure is representative, not measured. [TOM-REVIEW]